Research Catalog

Certified transmittance density uncertainties for standard reference materials using a transfer spectrophometer

Title
Certified transmittance density uncertainties for standard reference materials using a transfer spectrophometer / J. C. Travis, M. V. Smith, S. J. Choquette, Hung-Kung Liu.
Author
Travis, J. C.
Publication
Gaithersburg, MD : U.S. Dept. of Commerce, National Institute of Standards and Technology, 2011.

Available Online

https://purl.fdlp.gov/GPO/gpo97087

Details

Additional Authors
  • Choquette, S. J.
  • Liu, Hung-Kung
  • Smith, M. V.
  • National Institute of Standards and Technology (U.S.)
Series Statement
NIST technical note ; 1715
Uniform Title
NIST technical note ; 1715.
Subject
  • Neutral density filters
  • Spectrophotometry
Note
  • "CODEN: NTNOEF"--Title page verso.
  • "November 2011"
  • Contributed record: Metadata reviewed, not verified. Some fields updated by batch processes.
Call Number
GPO Internet C 13.46:1715
LCCN
GOVPUB-C13-4054ae43359288269ac3670aa8b8fdfa
OCLC
795837506
Author
Travis, J. C., author.
Title
Certified transmittance density uncertainties for standard reference materials using a transfer spectrophometer / J. C. Travis, M. V. Smith, S. J. Choquette, Hung-Kung Liu.
Publisher
Gaithersburg, MD : U.S. Dept. of Commerce, National Institute of Standards and Technology, 2011.
Description
1 online resource (14 pages) : illustrations.
Type of Content
text
Type of Medium
computer
Type of Carrier
online resource
Series
NIST technical note ; 1715
NIST technical note ; 1715.
Summary
Overall uncertainties are evaluated for the certification of transmittance density (absorbance referred to air) and regular spectral transmittance for solid neutral density filter Standard Reference Materials by means of a transfer spectrophotometer. Traceability is asserted by means of comparison measurements to a recognized reference spectrophotometer. The uncertainties are evaluated without bias correction, using the combination of the legacy combined standard uncertainty values with uncertainty components for the measured bias, the standard uncertainty of this measured bias, and the standard uncertainty characteristic of simple replication for a single measurement using the transfer spectrophotometer. Numerical results are given, and are anticipated to be the values initially quoted on certificates and in reports of recertification. However, these values are subject to change upon future adjustment of estimated uncertainty components for the filters or changes in the observed bias with future determinations.
Connect to:
https://purl.fdlp.gov/GPO/gpo97087
Added Author
Choquette, S. J., author.
Liu, Hung-Kung, author.
Smith, M. V., author.
National Institute of Standards and Technology (U.S.)
Other Standard Identifier
GOVPUB-C13-4054ae43359288269ac3670aa8b8fdfa
Gpo Item No.
0249-A (online)
Sudoc No.
C 13.46:1715
View in Legacy Catalog